8 ML/DAY CONTAINERISED MICROFILTRATION SYSTEM

For water recycling or wastewater treatment

OUR RENTAL SYSTEMS

MICROFILTRATION SYSTEM FOR WATER RECYCLING APPLICATION OR EFFLUENT TREATMENT

Asset ID MF-002

FOR SOLIDS REDUCTION FROM TREATED EFFLUENT

This system is capable of providing exceptional removal of suspended solids, organic material, coagulated solids, precipitated metals and biological material from low quality feed water including:

  • River water up to 30 NTU turbidity
  • Low quality borehole or spring water
  • Recovered rainwater
  • Low BOD water from vegetable washing operation
  • Low BOD treated effluent from industrial or municipal wastewater treatment
  • Mine drainage water

It will produce high quality filtrate water suited to a variety of applications

  • Cooling water for power generation
  • Reverse osmosis feedwater (ongoing treatment for boilers and power stations)
  • Water for irrigation or hydroponics or fish farming
  • Discharge to the environment in sensitive location

It is installed in 2 separate 40ft shipping containers and contains 4000 square metres of installed membrane area. For a wastewater recycling application we would propose a very conservative flux rate (e.g. 60 lmh) meaning that it is capable of producing over 5.7 million litres per day of microfiltered water with turbidity of less than 0.5 ntu

It includes a fully automatic clean-in-place and wastewater neutralisation system.

SPECIFICATIONS

PROCESS DESCRIPTION

Pressurised feed water is provided by a single external feed water pump to the membrane container and is processed in two separate streams that operate independently of each other. Each stream consists of 40 microfiltration membrane modules with 50 m2 of active membrane area in each module.

Filtrate water quality is monitored for turbidity and conductivity by instruments in the membrane container. Turbidity of the filtered water should be always less than 0.5 NTU irrespective of the feed water quality.

The membranes are maintained in operation by an automatic ‘flux maintenance’ (FM or backwash) operation. In wastewater recycling applications the backwash frequency will be determined according to the feedwater quality. There will be additional cycles of ‘enhanced flux maintenance’ when chemicals are used in a brief chemical cleaning cycle. Also longer cycles of more intensive chemical cleaning will be required from time to time and these can be programmed intoi the automatic operation of the systems.

Wastewater generated by the system consists of; 1) non-chemical wastewater – backwash waste from the membranes and the pre-screens containing suspended solids, and 2) Fully neutralised chemical cleaning solutions[1] which are suitable for discharge to public sewer without further treatment.

These systems will provide exceptional removal of suspended solids, flocculated / coagulated solids, precipitated metals and biological material and are therefore ideal for production of feed water to a reverse osmosis process.

The systems are fully automated once started. All backwashing, chemical cleaning and neutralisation/discharge is carried out automatically.

[1] neutralised solutions of sodium hypochlorite (neutralised with sodium bisulphite) and sodium hydroxide neutralised with citric or hydrochloric acid.

Please contact us for further information